检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曹希明[1] 郑君惠[1] 巫梓斌[1] 钟小梅[1] 李新云[1] CAO Ximing ZHENG Junhui WU Zibin ZHONG Xiaomei LI Xinyun(Department of Radiology, Guangdong General Hospital (Guangdong Academy of Medical Scaiences), Guangzhou 510080, China)
机构地区:[1]广东省人民医院(广东省医学科学院)放射科,广东广州510080
出 处:《中国医学影像学杂志》2017年第2期101-104,共4页Chinese Journal of Medical Imaging
摘 要:目的探讨低剂量(30 ml)对比剂在256层CT头颈部血管成像(CTA)中的可行性,在减少静脉对比剂聚集的同时保证动脉足够强化。资料与方法前瞻性选取头颈部CTA的患者60例,随机分为A、B组。两组扫描参数相同,对比剂注射方案不同。其中A组对比剂总量为60 ml,注射流速为4.0 ml/s,随后以相同速度注射30 ml生理盐水;B组对比剂总量为30 ml,注射流速5.0 ml/s,随后以相同速度注射50 ml生理盐水。分别测量两组图像颈动脉、上腔静脉、头臂静脉、锁骨下静脉及颈静脉的CT值,并对图像质量进行分析。结果 A、B两组上腔静脉、右头臂静脉及右锁骨下静脉CT值比较,差异有统计学意义(P<0.05)。A、B两组左头臂静脉、左锁骨下静脉、左右颈内静脉CT值比较,差异无统计学意义(P>0.05)。A、B两组主动脉弓、左右颈总动脉、左右锁骨下动脉及左右大脑中动脉CT值比较,差异有统计学意义(P<0.05)。A、B两组图像质量评分比较,差异有统计学意义(P<0.05)。结论在头颈部CTA检查中采用30 ml低剂量对比剂图像质量能够满足临床诊断需要,降低了对比剂的用量,并减少上腔静脉、右头臂静脉及右锁骨下静脉的对比剂聚集,减少硬化伪影,同时不影响动脉强化。Purpose To investigate the feasibility of 30 ml low-dose contrast medium in reducing the accumulation of contrast medium in venous system while maintaining enough artery enhancement in 256-slice CT angiography(CTA) of intracranial and cervical arteries. Materials and Methods Sixty patients with head and neck CTA were recruited prospectively, and they were randomly divided into group A and group B. The scan parameters of the two groups were identical, but the protocol of contrast medium injection was different. Group A was injected 60 ml contrast medium and 30 ml saline successively with the rate of 4.0 ml/s. Group B was injected 30 ml contrast medium and 50 ml saline successively with the rate of 5.0 ml/s. CT attenuation values of aortic arch, common carotid artery, subclavian artery, cerebral middle artery, superior vena cava, innominate vein, subclavian vein, internal jugular vein were measured, and the image quality was evaluated. Results The average CT values of superior vena cava, right innominate vein, right subclavian vein in two groups had significant differences(P〈0.05). The average CT values of left brachial vein, left subclavian vein, left and right internal jugular vein in two groups had no significant differences(P〉0.05). The average CT values of aortic arch, left and right common carotid artery, left and right subclavian artery, left and right cerebral middle artery in two groups had significant differences(P〈0.05). The scores of image quality in two groups also had significant difference(P〈0.05). Conclusion Head-and-neck CTA with 30 ml low-dose contrast medium is feasible and the images are satisfactory for diagnosis, which can reduce the dose of contrast medium and accumulation of contrast medium in venous system, while maintaining enough artery enhancement.
关 键 词:头部 颈 脑血管造影术 血管造影术 体层摄影术 螺旋计算机 造影剂
分 类 号:R445.3[医药卫生—影像医学与核医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.218.77