独立化霜传感器对热泵热水器化霜的优化分析  被引量:2

Analysis of Separate Frost Sensor in Heat Pump Water Heater Frosting

在线阅读下载全文

作  者:钟晓辉 郭晓静 ZHONG Xiao-hui GUO Xiao-jing(China Architectural design institute Co., Ltd)

机构地区:[1]中国建筑设计院有限公司

出  处:《建筑热能通风空调》2017年第4期15-17,共3页Building Energy & Environment

摘  要:在对翅片管式蒸发器结霜的理论与实践研究分析基础上,提出了空气源热泵热水器系统外机单独设立化霜温度传感器的系统优化方案,并对独立的化霜温度传感器进行理论和实验分析,提出了合适的化霜温度传感器位置可对空气源热泵热水器化霜周期及化霜效果优化的观点。Based on the theory and practice research of the finned tube evaporator frosting analysis, a new program thatsetting separate frost temperature sensor in the air source heat pump water heater system was suggested, and theindependent frost temperature sensor from theoretical and experimental was analyzed, and the point of view that thesuitable frost temperature sensor location can improve the air source heat pump water heater frost cycle and frost effectwas put forward.

关 键 词:空气源热泵热水器 化霜 翅片管式蒸发器 

分 类 号:TU822[建筑科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象