660MW超临界墙式切圆煤粉锅炉烟温偏差优化控制  被引量:19

Optimal Control of Gas Temperature Deviation in a 660 MW Supercritical Tangentially-fired Boiler

在线阅读下载全文

作  者:郭岸龙 方庆艳[1] 赵斯楠 吴英[2] 夏永俊[2] 张成[1] 陈刚[1] 

机构地区:[1]华中科技大学煤燃烧国家重点实验室,武汉430074 [2]国网江西省电力科学研究院,南昌330096

出  处:《动力工程学报》2017年第5期341-348,共8页Journal of Chinese Society of Power Engineering

摘  要:对某电厂660 MW超临界墙式切圆煤粉锅炉炉膛出口烟温偏差过大现象进行了数值模拟,并将模拟结果与试验结果进行了比较.结果表明:模拟结果与试验结果吻合较好;残余旋转气流造成了烟温偏差;将SOFA水平摆角反切、减小二次风挡板开度和增大SOFA挡板开度,均有利于降低炉膛出口烟温偏差;通过采取上述措施,提高了锅炉的经济性与安全性.Aiming at the phenomenon of large gas temperature deviation between the left and right side at furnace outlet of a 660 MW supercritical tangentially-fired boiler, numerical simulation was conducted, and subsequently the results were compared with that of experiment. Results show that the simulation data a- gree well with experimental values, and the gas temperature deviation is found to be caused by residual ro- tating air flow, which can be reduced by counterclockwise adjusting the SOFA horizontal swing angle, re- ducing the opening of secondary air damper and increasing the opening of SOFA damper, etc. After taking above measures, the economy and safety of the boiler are improved.

关 键 词:墙式切圆燃烧 烟温偏差 SOFA 二次风 

分 类 号:TK229.6[动力工程及工程热物理—动力机械及工程]

 