机构地区:[1]中国石油管道局工程有限公司设计分公司,河北廊坊065000 [2]中国石油管道科学研究院,河北廊坊065000
出 处:《消防科学与技术》2017年第4期480-482,共3页Fire Science and Technology
摘 要:为探讨国内外内浮顶储罐泡沫灭火系统设计差异,结合国外某工程设计实例对国内外标准进行了对比分析,介绍了NFPA标准和我国国家标准中对大型内浮顶储油罐泡沫灭火系统的相关规定,分析比较了两个标准在低倍数泡沫灭火系统设计参数及泡沫灭火设施布置等方面的差异,并给出低倍数泡沫灭火系统设计的合理化建议。In order to discuss the difference in design of foam extinguishing system for inner floating roof tank in china and abroad,the comparative analysis on design code and standard in China and abroad were compared combining with the design example of overseas project,the foam extinguishing system of large_scale inner floating roof tank in NFPA and national standards were introduced,the differences in design parameters and facilities layout of low expansion foam extinguishing system were introduced,and the advices for design of foam extinguishing system were provided.