检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]温州排水有限公司,浙江温州325000 [2]中国市政工程华北设计研究总院有限公司,天津300381
出 处:《中国给水排水》2017年第10期34-36,共3页China Water & Wastewater
摘 要:以往污水处理厂设计中对碱度关注较少,在原污水TN、NH_3-N浓度大幅度增大而排放浓度要求更低的条件下,TN、NH_3-N的处理成为目前污水处理厂设计、运行的主要矛盾之一,污水碱度是其重要影响因素之一。从硝化反硝化原理、碱度来源及其影响、污水处理工艺对碱度的影响、调整碱度药剂的选择等方面进行了论述,提出对污水处理过程中碱度的设计要求,以确保出水NH_3-N达标。The importance of alkalinity is always neglected in the design process of wastewater treatment plant. Under the conditions of increasing influent TN, NH3 - N concentration and the requirement of decreasing effluent concentration, controlling TN, NH3 - N removal performance has become an issue in the design and operation of wastewater treatment plant. Then, as one of the important factors in the nitrogen removal process, alkalinity ought to be paid much attention. In this paper, all the following aspects have been discussed, such as the principle of nitrification/denitrification, source and effect of alkalinity, influence of wastewater treatment mode on alkalinity variation, and alkalinity controlling by chemicals. Finally, the requirement of alkalinity level and controlling in design process has been put forward to ensure the effluent NH3 -N below the standard.
分 类 号:X703[环境科学与工程—环境工程]