绝缘子自然积污测量方案研究  被引量:2

Study on Measurement Scheme of Natural Contamination for Insulators

在线阅读下载全文

作  者:石鼎[1] 韩刚[1] 谷彩连[1] 

机构地区:[1]沈阳工程学院电力学院,沈阳110136

出  处:《绝缘材料》2017年第5期63-66,共4页Insulating Materials

摘  要:为研究绝缘子自然积污试验数据的可信度与准确性,以瓷绝缘子和复合绝缘子为试品进行人工染污试验,探讨不同测量方法对绝缘子表面盐密和灰密的影响。结果表明:在相同的测量方式下,传统法测量盐密灰密的效果比专业试纸、湿巾、棉球擦拭等方法好;受污情况越严重,各种测量方式的测量结果差距也越大。Abstraet: To study the reliability and accuracy of natural contamination test data for insulators, artificial contamination tests were conducted on porcelain insulator and composite insulator, and the effects of different measuring methods on the salt deposit density (ESDD) and dust density (NSDD) of insulators were discussed. The results show that under the same test method, the traditional method is more effective to measure ESDD and NSDD than the professional test paper, wet tissue, and cotton ball methods. The more serious of the contamination, the bigger the difference of measuring methods is. The test results provide reference to the selection of natural contamination measurement scheme for insulators. Key words: ESDD; NSDD; insulator; measuring method; pollution flashover

关 键 词:盐密 灰密 绝缘子 测量方式 污秽闪络 

分 类 号:TM207[一般工业技术—材料科学与工程]

 