火焰原子吸收光谱法直接测定锡阳极泥中的银  被引量:11

Determination of Silver in Tin Anode Slime by Flame Atomic Absorption Spectrometry

在线阅读下载全文

作  者:冯振华[1] 王可伟 FENG Zhenhua WANG Kewei(Beijing General Research Institute of Mining and Metallurgy ,Beijing 102628, China Beijing Yadilite Aviation Advanced Materials Corporation ,Beijing 101500, China)

机构地区:[1]北京矿冶研究总院,北京102628 [2]北京雅迪力特航空新材料股份公司,北京101500

出  处:《中国无机分析化学》2017年第2期59-62,共4页Chinese Journal of Inorganic Analytical Chemistry

摘  要:建立了火焰原子吸收光谱法(FAAS)测定锡阳极泥中银含量的方法。文章考察了不同的测定介质、酸度对测定结果的影响。实验结果表明在选定条件下,锡阳极泥中的锡、锑、铅等杂质不干扰银的测定。方法加标回收率在99.2%~103%,精密度实验结果表明,相对标准偏差(RSD,n=11)均小于4%。操作过程简单,能满足生产的需要。A method for the determination of silver in tin anode slim by flame atomic absorption spectrometry (FAAS) was developed. The effects of media and acidity on the determination were investigated. Under the selected conditions, the impurities such as tin, antimony and lead in tin anode mud did not interfere with the determination of silver. Values of recovery were in the range of 99.2% to 103% and the result of precision test showed that RSD(n=11) was less than 4%. This method is simple and can meet the testing requirements for daily analysis of impurity elements in tin anode slime.

关 键 词:火焰原子吸收光谱法 锡阳极泥  

分 类 号:O657.31[理学—分析化学] TH744.12[理学—化学]

 