作 者:庄培峰[1] 黄建军[1] 朱祖巍[1] 王小勇[1] ZHUANG Peifeng HUANG Jianjun ZHU Zuwei WANG Xiaoyong(Second Department of Orthopedics, Ningde Hospital Affiliated to Fujian Medical University, Fujian Province, Ningde 352100, China)
机构地区:[1]福建医科大学附属宁德市医院骨二科,福建宁德352100
出 处:《中国医药导报》2017年第15期102-105,共4页China Medical Herald
摘 要:目的比较近端防旋髓内钉与近端锁定钢板治疗老年股骨转子间不稳定骨折的效果。方法回顾性分析福建医科大学附属宁德市医院2011年2月~2016年1月收治的120例老年股骨转子间不稳定骨折患者临床资料,依据治疗措施不同进行分组,近端防旋髓内钉组(60例)和近端锁定钢板组(60例)。观察两组老年股骨转子间不稳定骨折患者切口长度、手术时间、术中出血量、术后负重时间、住院天数、骨折愈合时间、术后功能恢复效果、术后并发症情况。结果防旋髓内钉组切口长度、手术时间、术中出血量、术后负重时间、住院天数、骨折愈合时间均低于锁定钢板组,防旋髓内钉组术后功能恢复优良率高于锁定钢板组,防旋髓内钉组切口感染、下肢静脉血栓、大转子部疼痛不适、髋关节内翻均低于锁定钢板组,差异均有统计学意义(P<0.05)。结论近端防旋髓内钉治疗老年股骨转子间不稳定骨折,创伤小,疗效好,并发症少,值得临床推广应用。Objective To compare the effect of treatment agedness unstable fracture between femur rotor by proximal screw intramedullary nail and proximal locking plate. Methods From February 2011 to January 2016, in Ningde Hospital Affiliated to Fujian Medical University, clinical data of agedness unstable fracture between femur rotor patients (120 cases) were retrospectively analyzed, they were divided into two groups by different treatment methods, proximal screw intramedullary nail group (60 cases) and proximal locking plate group (60 cases). The incision length, operation time, intraoperative blood loss, load time after operation, hospital stay, fracture healing time, functional recovery effect after operation, postoperative complications of agedness unstable fracture between femur rotor patients in two groups were detected. Results The The incision length, operation time, intraoperative blood loss, load time after operation, hospital stay, fracture healing time of proximal screw intramedullary nail group were lower than proximal locking plate group, the functional recovery good rate after operation of proximal screw intramedullary nail group were higher than proximal locking plate group, the incision infection, LDVT, big rotor pain caused discomfort, hip varus of proximal screw intramedullary nail group were lower than proximal locking plate group, the differences were statistically significant (P 〈 0.05). Conclusion The treatment agedness unstable fracture between femur rotor by proximal screw intramedullary nail, trauma is little, curative effect is good, complication is little, it is worth to be used.
关 键 词:近端防旋髓内钉 近端锁定钢板 老年股骨转子间不稳定骨折 比较
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.118.37.224