检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:石生旺 SHI Shengwang(Guangdong Shaoguan Power Plant,Shaoguan,Guangdong 512132,China)
出 处:《广东电力》2017年第5期77-80,86,共5页Guangdong Electric Power
摘 要:对厂用电快速切换装置切换过程引起低压接触器低压释放问题进行分析的同时,结合试验数据提出无扰动切换的时间概念。对装置切换判据、采样计算周期及程序触发逻辑进行完善和优化,提高切换装置的切换速度,实现厂用电高压、低压系统无扰动切换,对参数整定也提出相关建议。At the same time of analyzing low voltage release of low voltage contactor in the process of auxiliary power fast transfer device switching, this paper also presents undisturbed switching time concept based on experimental data. It tries to complete and optimize switching criterion, sampling calculation cycle and trigger logic of the procedure so as to improve switching speed of the device and realize undisturbed switching of the high voltage system and the low voltage system. It pro-poses suggestions about parameter setting as well
关 键 词:无扰动切换跳用判据释放电压 中断.周斯
分 类 号:TM621.6[电气工程—电力系统及自动化]