检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吕连洁[1] 谢一工[1] 欧立权[1] 孙榕华 赵玺[1] 王杰鸿
机构地区:[1]云南电网有限责任公司昆明供电局,昆明650011
出 处:《云南电力技术》2017年第2期77-78,共2页Yunnan Electric Power
摘 要:针对地区配网自动化水平低、故障快速复电效率低的问题,提出了一种配网故障快速复电二分法,建立了不同供电区域下的配网故障快速复电时间模型,并分析了配网故障快速复电二分法在昆明电网故障处理中的应用成效,实践证明该方法能够减少配网故障处理时间,提升配网故障快速复电效率。Aiming at the problem of the distribution network, such as the Low level of automation and the low restoration efficiency of distribution network fault, the idea of lean management into distribution network management is proposed, and a rapid restoration time model of different power supply area for distribution network fault is obtained, the application effectiveness of a bisection method of Rapid Restoration in Ktmming distribution network fault handling is analyzed. The practice proves that the bisection method of Rapid Restoration can reduce the time of fault handling and improve the rapid restoration efficiency of distribution network fault.
关 键 词:配网故障 快速复电 不同供电区域 二分法 效率分析
分 类 号:TM73[电气工程—电力系统及自动化]