Comparative prospective study between medial and lateral distal tibial locking compression plates for distal third tibial fractures  被引量:8

Comparative prospective study between medial and lateral distal tibial locking compression plates for distal third tibial fractures

在线阅读下载全文

作  者:Sandeep Garg Vikram Khanna Mahaveer Prashad Goyal Narendra Joshi Amrut Borade Ishan Ghuse 

机构地区:[1]Department of Orthopaedics, Sawai Mansingh Medical College & Affiliated Hospital, Jaipur, India [2]Department of Orthopaedics, National Institute of Medical Sdences, Jaipur, India

出  处:《Chinese Journal of Traumatology》2017年第3期151-154,共4页中华创伤杂志(英文版)

摘  要:Purpose: Tibial fracture is the most common long bone fracture. Distal third tibial fractures are chal- lenging though open reduction and plating can result in anatomical reduction and rigid fixation. This paper aimed to evaluate and compare the results of medial and lateral locking compression plates for distal third tibial fractures. Methods: This prospective clinical study involved 36 patients with distal tibial fractures admitted in Department of Orthopaedics, Sawai Mansingh Medical College & Affiliated Hospital, Jaipur, India, from June 2011 to May 2012, including 29 closed fractures and 7 open fractures at the mean age of 38.9 years. Thirty-six patients were divided equally into two groups based on treatment method, including medial plating group (18 patients) and lateral plating group (18 patients). They were followed up for at least 5 months after discharge. The functional outcomes were evaluated using Tenny and Wiss clinical assess- ment criteria. Results: Malunion was found in 3 cases of medial plating group and in 1 case of lateral plating group. In the medial plating group, there were 5 cases of superficial infections, 1 deep infection, 1 nonunion and 3 wound dehiscence. In the lateral plating group, there was 1 case of superficial infections, 1 deep infection and 1 nonunion, in the lateral plating group, 4 patients reported feeling the plates and screws but none of them asked to remove the hardware. In the medial plating group, 9 patients reported symptomatic hardware problems and 7 asked to remove the hardware. The number of cases graded as excellent/good/ fair was 1/8/7 in the medial plating group and 3/7/7 in the lateral plating group respectively. In the medial plating group, the final range of motion was 17.2° in ankle dorsiflexion and 30.7° in ankle plantar flexion. In the lateral plating group, the final range of motion was 19° in ankle dorsiflexion and 34.2° in ankle plantar flexion. Conclusion: Lateral plating of distal tibia is safe and feasible, which can provide biol

关 键 词:Tibial fractures Bone plates Open fracture reduction 

分 类 号:R687.3[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象