60 kW高频高压变压器的绝缘研究  被引量:1

Study on Insulation of 60 kW High Frequency High Voltage Transformer

在线阅读下载全文

作  者:王泽庭[1] 李敬文[2] 樊生文[3] 

机构地区:[1]北方工业大学北京市变频技术工程技术研究中心,北京100144 [2]北方工业大学北京市电力节能关键技术协同创新中心,北京100144 [3]北方工业大学北京电动车辆协同创新中心,北京100144

出  处:《绝缘材料》2017年第6期43-47,共5页Insulating Materials

摘  要:以60 k W电子束焊机用高频高压变压器建立模型,通过比较3种绕制方法对电场强度的影响,并利用有限元软件Ansoft在静电场条件下对C型法和Z型法的场强和电位分布进行仿真分析。结果表明:C型法的场强分布比Z型法的场强分布更均匀,变压器绕组两端的端电势最高,所以在进行绝缘处理时要尤其注意绕组两侧的绝缘。A high frequency high voltage transformer model for 60kW electron beam welder was built. The effects of three winding methods on the electric field intensity were compared, and the field intensity and potential distribution of type C method and type Z method were simulated using the finite element software Ansoft under electrostatic field condition. The results show that the field intensity distribution of type C method is more uniform than that of type Z method, and the highest electric potential appears at the both ends of transformer winding, so the insulation on both sides of the winding should be particularly concerned in insulation treatment.

关 键 词:高频高压变压器 绕线方法 绝缘 

分 类 号:TM403.2[电气工程—电器]

 