电站热力试验流量测量方法对比分析及其应用  

Comparison and Analysis of Flow Measurement Methods and Their Application in Power Station Thermal Test

在线阅读下载全文

作  者:王加勇[1,2] 杨茉[1] 张鼎[2] 代军科 刘国伟[2] 

机构地区:[1]上海理工大学能源与动力工程学院 [2]苏州热工研究院有限公司

出  处:《化工自动化及仪表》2017年第6期538-541,549,共5页Control and Instruments in Chemical Industry

摘  要:以某330MW火力发电厂进除氧器的凝结水流量为例,分析采用超声波流量计、ASME流量喷嘴、标准孔板流量计测量流体参数和具体管道的条件要求,并对实际应用测量结果进行分析比较。结果表明:机组考核试验以ASME流量喷嘴测量的凝结水流量作为基准;日常对比试验标准孔板流量计测量能满足要求;超声波流量计误差较大,可以测量对试验结果影响较小的辅助流量。Taking condensation water flow in the deaerator of a 330MW coal-fired power plant as an example, and making use of the ultrasonic flowmeter, the ASME flow nozzle and the standard orifice plate flowmeter to respectively measure parameters and analyze specific pipeline conditions were implemented. Comparatively an- alyzing the measured results and taking the condensation water flow measured by ASME flow nozzle as the benchmark show that, the measurement with standard orifice plate flowmeter can meet requirements and the ul- trasonic flowmeter has obvious error in measurement and it can be applied to the measurement of auxiliary flow which influences the test results less.

关 键 词:流量测量 ASME喷嘴 标准孔板 超声波流量计 

分 类 号:TH814[机械工程—仪器科学与技术]

 