检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王小华
机构地区:[1]溧阳市福沃特电力自动化有限公司
出 处:《黄金》2017年第6期44-47,共4页Gold
摘 要:低压漏电保护在金属矿山的使用越来越普遍。分析了中性点接地和中性点不接地2种接地方式的漏电特点、区别及其漏电保护原理,提出金属矿山低压漏电保护使用中存在的问题和产生的原因,介绍了适用于金属矿山漏电保护的JD低压漏电保护系统。工程实践表明:JD低压漏电保护系统能够使变电所出线和设备终端实现分级选择性漏电保护。The application of low-voltage leakage protection in metal mines is increasingly common now. This pa-per analyzed the characteristics of leakage under neutral grounding and ungrounding modes, the difference between them and their leakage protection mechanism ; presented existing problems and their causes in the application of low- voltage leakage protection ; introduced the JD low-voltage leakage protection system applicable to low-voltage leakage protection in metal mines. Engineering practice shows that the JD low-voltage leakage protection system can achieve graded and selective leakage protection for substation outlets and device terminals.
正在载入数据...