检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张益海 张催[1] 潘小东[1] 商宏杰[1] 骆岩红[1] 马思汉 李公平[1]
出 处:《无损检测》2017年第6期8-12,共5页Nondestructive Testing
基 金:兰州大学中央高校基本科研业务费专项资金资助项目(lzujbky-2016-32;lzujbky-2016-208)
摘 要:锥束X射线CT系统中,X射线束具有宽能谱的特性,会导致X射线硬化效应的产生,从而使得重建图像中出现杯状和条状伪影等,故有必要研究硬化校正方法以减少硬化效应带来的影响。提出了基于试验能谱和蒙特卡罗模拟的多项式拟合硬化校正方法,基于试验测量X射线初始能谱,利用蒙特卡罗模拟得到透射厚度与多能投影的关系,再利用多项式拟合得到多能投影与等效单能投影的转换关系,从而实现硬化校正。分别采用该方法和传统的滤波片法对一铝制标准件进行射束硬化校正试验。结果表明,所提出的方法比滤波片法能更好地消除锥束CT的硬化伪影。Since the X-ray beam has the characteristics of wide spectrum in the cone beam X-ray computed tomography imaging system,this leads to the X-ray hardening effect,so as to make the reconstruction image in the goblet artifact and strip artifact.It is necessary to study methods of the hardening correction in order to reduce the effects of hardening effect.A method of beam hardening correction is put forward,which is based on the experimental spectrum and Monte Carlo simulation of polynomial fitting.Based on the initial X-ray energy spectrum by experimental measurement,the relationship between transmission thickness and pluripotent projection can be obtained by exploiting Monte Carlo simulation.And then using polynomial fitting can obtain relationship between pluripotent projection and equivalent single projection,so as to realize hardening correction.This method and the traditional filter method for X-ray hardening correction on the aluminum workpiece were respectively used.The experimental results show that the proposed method is better than the filter method which can decrease cone-beam CT beam hardening artifacts effectively.It provides an effective correction method for cone beam industrial computed tomography beam hardening correction.
分 类 号:TL99[核科学技术—核技术及应用] TG115.28[金属学及工艺—物理冶金]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222