湿式电除尘器用导电玻璃钢的性能研究  被引量:3

Study on the Performance of Conductive FRP for Wet Electrostatic Precipitator

在线阅读下载全文

作  者:郑晓盼 葛平 朱召平 信明勋 邓正燕 钟永生 Zheng Xiaopan Ge Ping Zhu Zhaoping Xin Mingxun Deng Zhengyan Zhong Yongsheng(Fujian Longking Co. , Ltd. , Longyan 364000 Jinling Aliancys Resin Co. , Ltd. , Nanjing 211050)

机构地区:[1]福建龙净环保股份有限公司,龙岩364000 [2]金陵力联思树脂有限公司,南京211500

出  处:《玻璃纤维》2017年第3期26-30,共5页Fiber Glass

基  金:福建省科技计划项目"燃煤电站用管式湿式电除尘(雾)技术开发及应用"(2017Y3006)

摘  要:参照美国标准ASTM C581,采用加速试验的方法对拉挤、手糊、缠绕工艺生产的导电玻璃钢管样块,在质量浓度为50%、温度为80℃的硫酸水溶液中进行28 d的浸泡试验,并周期性地测试其弯曲强度和弯曲模量,基于弯曲强度保留率指标对不同工艺生产的阳极管的耐腐蚀性能进行研究。According to the US standard ASTM C581,the conductive FRP tube samples produced by pultrusion, hand lay-up and winding process were subjected to 28 days of soaking in sulfuric acid aqueous solution with mass concentration 50% and at 80 ℃ by means of accelerated test. The corrosion resistance of the anode tubes produced by different processes was studied by periodically testing the flexural strength and flexural modulus and based on their chemical strength retention.

关 键 词:湿式电除尘器 导电玻璃钢 拉挤工艺 耐腐蚀试验 