丁二烯装置脱重塔系统腐蚀分析及整改预防  被引量:3

Analysis and Prevention of the Corrosion Problem of Heavy Component Removal Tower System in Butadiene Unit

在线阅读下载全文

作  者:穆青[1] 邓有恒 李洪峰[3] 

机构地区:[1]中国石油抚顺石化公司石油三厂,辽宁抚顺113001 [2]江苏斯尔邦石化有限公司丙烯腈事业部,江苏连云港222000 [3]中国石油抚顺石化公司烯烃厂,辽宁抚顺113004

出  处:《当代化工》2017年第6期1176-1178,1182,共4页Contemporary Chemical Industry

摘  要:某石化公司丁二烯抽提装置脱重塔塔顶回流系统冷凝器及液相管线发生多处腐蚀泄漏现象,通过分析发现为乙酸腐蚀和氨腐蚀所致。通过优化工艺操作、冷凝器检修、管线焊缝检查消缺等措施,消除腐蚀泄漏隐患,保证丁二烯装置安全环保生产,长周期运行。The corrosion mechanism of reflux condensers and accessory pipelines in a striping tower of butadiene plant of a petrochemical company was discussed. It's found that the corrosion was caused by acetic acid as well as ammonia. Some measurements to eliminate corrosion leakage hidden dangers were put forward, such as operation optimization, equipment maintenance and on-line welds X-ray inspection and so on.

关 键 词:丁二烯装置 乙腈 乙酸 腐蚀 

分 类 号:TQ221[化学工程—有机化工]

 