Energy response correction for an electronic personal dosimeter using the channel ratio method  

Energy response correction for an electronic personal dosimeter using the channel ratio method

在线阅读下载全文

作  者:Ping Huang You-De Zhang Yong Yang Cong-Hua Zhang Lan Gong Qian Yang 

机构地区:[1]National Institute of Measurement and Testing Technology,Chengdu 610021, China [2]Sichuan Radiation Technology Co., Ltd., Chengdu 610021,China [3]Nimtt Measurement and Testing Technology, Ltd,Chengdu 610021, China

出  处:《Nuclear Science and Techniques》2017年第7期65-72,共8页核技术(英文)

基  金:supported by the National Key Scientific Instruments To Develop Dedicated(2013YQ090811)

摘  要:An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accurate monitoring of personal dose equivalent H_p(10)parameters for radiation workers.For this reason,in this paper we propose a method of combining composite screen detection technology,multichannel measurement technology,and the channel ratio method to achieve accurate measurement of the personal dose equivalent parameters.According to China National Standard GB/T 13161-2003 and National Verification Regulation JJG 1009-2006,the instrument was tested in the energy range between 48 keV and 1.25 MeV.The experimental results showed that the difference of energy response to ^(137)C_S corrected by the new method was almost constant within ±6.0%,which fulfilled the ±30% requirement of GB/T 13161-2003 and JJG1009-2006.Meanwhile,the method proposed obtained energy information regarding the radiation field.An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accurate monitoring of personal dose equivalent Hp10 parameters for radiation workers.For this reason,in this paper we propose a method of combining composite screen detection technology,multichannel measurement technology,and the channel ratio method to achieve accurate measurement of the personal dose equivalent parameters.According to China National Standard GB/T 13161-2003 and National Verification Regulation JJG 1009-2006,the instrument was tested in the energy range between 48 keV and 1.25 MeV.The experimental results showed that the difference of energy response to ^137CS corrected by the new method was almost constant within ±6.0%,which fulfilled the ±30% requirement of GB/T 13161-2003 and JJG1009-2006.Meanwhile,the method proposed obtained energy information regarding the radiation field.

关 键 词:能量响应 多通道 个人剂量计 正电子 PIN光电二极管 个人剂量当量 电子个人剂量仪 Γ射线探测器 

分 类 号:TL818[核科学技术—核技术及应用]

 