彩色多普勒闪烁伪像诊断膀胱结石临床价值的研究  被引量:3

The diagnostic value of the twinkling artifact in bladder stone

在线阅读下载全文

作  者:米加[1] 初晓凌 王星[1] 孙英姿[1] 吴丽萍[1] 马艳红[1] 姜士芹[1] 刘鸿玉[1] 

机构地区:[1]山东省交通医院超声科,山东济南250031

出  处:《医学影像学杂志》2017年第7期1327-1329,共3页Journal of Medical Imaging

摘  要:目的探讨彩色多普勒闪烁伪像诊断膀胱结石的临床价值。方法选取经CT检查证实的膀胱单发结石患者132例,运用二维超声测量结石大小并进行分组,观察并记录各组结石后方声影显示情况,应用彩色多普勒超声观察并记录各组结石后方闪烁伪像显示情况,对显示率进行统计分析。结果 132例膀胱结石声影显示率为72.7%,闪烁伪像显示率为84.8%,差异有统计学意义。A组(d≤10mm)膀胱结石共40例,声影显示率为42.5%、闪烁伪像显示率为80.0%,差异有统计学意义;B组(11mm≤d≤20mm)膀胱结石共65例,声影显示率为86.2%、闪烁伪像显示率为86.2%,差异无统计学意义;C组(d≥21mm)膀胱结石共27例,声影显示率为85.2%、闪烁伪像显示率为88.9%,差异无统计学意义。结论彩色多普勒闪烁伪像诊断膀胱结石具有重要意义,尤其对于诊断较小膀胱结石更具临床价值。Objective To evaluate the diagnostic value of the twinkling artifact in bladder stone.Methods A total of 132 patients with single bladder stones were enrolled in the study from February 2015 to December 2016.All bladder stones were confirmed by non-contrast helical computerized tomography.The bladder stones were classified into grades according to stone size.The acoustic shadowing (AS) and twinkling artifact (TA) level of bladder stones were confirmed with gray-scale imaging and CDFI.The incidence of AS and TA was comparatively analyzed.Results There was significant difference in the incidence between the AS(72.7%) and TA(84.8%) of 132 bladder stones(P〈0.05).A significant difference in the incidence was observed between the AS(42.5%) and TA(80.0%) of the bladder stones in grade A(d≤10 mm)(P〈0.05).There was no statistically significant difference in the incidence between the AS(86.2%) and TA(86.2%) of the bladder stones in grade B(11 mm≤d≤20 mm), and between the AS(85.2%) and TA(88.9%) of the bladder stones in grade C(d≥21 mm)(P〉0.05).Conclusion The twinkling artifact is useful in the diagnosis of bladder stone, especially in small stone.

关 键 词:闪烁伪像 膀胱结石 超声检查 

分 类 号:R445.1[医药卫生—影像医学与核医学] R694[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象