检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国南方电网电力调度控制中心,广州510663
出 处:《南方电网技术》2017年第6期8-14,共7页Southern Power System Technology
摘 要:根据南方电网异步联网后的结构特点,提出了基于鲁西背靠背柔性直流系统的南方电网黑启动方案。首先,从云南异步联网运行的特点及对南方电网黑启动目标网架的影响出发,分析了鲁西背靠背柔性直流系统应用于电网黑启动的优势,提出了柔性直流系统的黑启动策略。在此基础上,研究了基于柔性直流系统的南方电网黑启动方案,并给出了利用鲁西背靠背柔性直流系统恢复云南电网和南方电网主网的详细路径和具体步骤。最后,通过现场试验和RTDS仿真验证了所提黑启动方案的可行性和有效性。Based on the structure characteristics of China Southern Power Grid( CSG) after asynchronous interconnection,this paper proposes the black-start scheme of CSG based on Luxi Back-to-back VSC-HVDC System. Firstly,from the characteristics of asynchronous interconnection of Yunnan power grid and its impact on the target framework of the black-start stage of CSG,the advantages of Luxi Back-to-back VSC-HVDC being applied to power grid black-start are analyzed and the black-start strategy of VSC-HVDC system is proposed. Then,the VSC-HVDC based black-start scheme suitable for CSG is put forward,meanwhile the start-up paths and operation steps to restore Yunnan power grid and the main grid of CSG with Luxi Back-to-back VSC-HVDC system are presented. At last,field test and RTDS simulation verify the validity and effectiveness of the proposed black-start strategy.
关 键 词:黑启动 异步联网 柔性直流系统 背靠背 模块化多电平换流器
分 类 号:TM711[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.179.147