检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄金浩 高闯[1] 张志飞[1] 苏万强[1] 王鹏[1] 魏文桂[1] 孙健[1] 江荣才[1]
出 处:《中华实验外科杂志》2017年第8期1299-1302,共4页Chinese Journal of Experimental Surgery
基 金:国家自然科学基金(81271359);天津市科技计划项目(14ZCZDSY00179)
摘 要:目的 比较3款常用图像分析软件对细胞因子矩阵(Cytokine Array)相同任意蛋白点表达的差异,优选出最适图像分析软件.方法 从本实验室获得的一对Cytokine Array图像,任选图上4个蛋白点,以3款图像分析软件(Gel-Pro analyzer/Labwork、Quantity One和Image J)反复分析其蛋白丰度,比较其复杂性和可重复性,并针对入选蛋白,行酶联免疫吸附试验(ELISA)对比验证其吻合程度.结果 3款分析软件分析过程的复杂程度由简到繁依次为Gel-Pro analyzer/Labwork、Quantity One和Image J;可重复性从大到小(即变异系数从小到大)依次为Gel-Pro analyzer/Labwork(0.00%)、Quantity One(5.07%)和Image J(9.75%);若以ELISA(81.49%)结果为标准参考值,则吻合度从高到低依次为Quantity One(71.61%)、Image J(67.27%)、Gel-Pro analyzer/Labwork(62.31%).结论 各种软件均具备独自特点,如果仅作定性分析,推荐Gel-Pro analyzer/Labwork;如果作半定量分析,推荐Quantity One.若综合可重复性、分析过程的复杂程度、与ELISA结果的吻合程度,则推荐Quantity One.Objective In order to preferentially select the most suitable image analysis software for the abundance analysis of the proteinic spot of Cytokine Array,we compared 3 kinds of image analysis software in analyzing the randomly selected proteinic spots of the Cytokine Array.Methods Four proteinic spots were randomly selected from a pair of Cytokine Array images obtained in our lab.Three image analysis softwares of Gel-Pro analyzer/Labwork,Quantity One and Image J were applied to repeatedly analyze the abundance of the selected proteinic spots.The repeatability and complexity of the analysis procedures of these softwares were assayed.In order to test whether the software analysis result agreed to that of the enzyme linked immunosorbent assay (ELISA),the abundance of the corresponding proteins of the selected proteinic spots were also assayed with ELISA.Results The highest and lowest repeatability of the analysis result of the software ranked as Gel-Pro analyzer/Labwork,Quantity One and Image J.The least and the most procedure complexity of the software was Gel-Pro analyzer/Labwork,Quantity One and Image J.The best to the poorest agreement degrees of the software analysis results with the ELISA assay ones were Quantity One,Image J and Gel-Pro analyzer/Labwork.Conclusion In the proteinic spots evaluation in Cytokine Array analysis,the Gel-Pro analyzer/Labwork is suggested for qualitative analysis and the Quantity One is recommended for semi-quantitative analysis.If taking into account the repeatility,complexity and agreement to ELISA,the Quantity One is proposed first.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222