摘 要:目的:初步评价Carelink远程监测系统在临床医生中的易用性。方法:前瞻性入选2012-01至2013-10在全国12家医院已经植入具有Carelink远程监测功能的心血管植入型电子器械(CIED)的患者215例,平均年龄(62.3±14.3)岁,其中男性108例,女性107例。共有54名临床医生填写了调查问卷。为便于分析,根据患者随访调查CIED的不同,将患者和临床医生各分为植入起搏器(PM)组110例和30名、植入型心律转复除颤器(ICD)组54例和10名、心脏再同步化治疗(CRT)组51例和14名。患者需在入选后3个月时进行1次院内常规随访,记录临床医生随访患者使用时间。此外,患者还需应用Carelink远程监测仪在入选后3、6个月时传输CIED信息完成Carelink远程随访。在3个月Carelink远程随访时收集医生数据查看时间,在6个月随访时针对Carelink远程随访系统的使用情况对临床医生进行问卷调查。结果:54名临床医生均认为Carelink远程监测系统操作简单,容易使用。有147例患者完成了3个月院内常规随访,临床医生院内常规随访平均时间为(14.8±8.4)min;150例患者完成了3个月Carelink远程随访,Carelink远程随访平均时间为(8.2±4.6)min,差异有统计学意义(P<0.0001)。结论:对于临床医生而言,Carelink远程监测系统使用容易,操作简单,满意程度高,可以节约随访时间。Objective: To conduct a preliminary evaluation for the usability of Carelink remote monitoring system by clinical physician. Methods: A total of 215 patients received cardiovascular implantable electronic devices(CIED) with Carelink remote monitoring function from 12 hospitals in China between 2012-01 and 2013-10 were prospectively enrolled. The patient's mean age was(62.3±14.3) years including 108 male and 107 female. There were 54 physicians completed questionnaire survey. Based on the type of CIED, the patients were divided into3 groups: PM(pace maker) group, n=110, ICD(implantable cardioverter defibrillator) group, n =54 and CRT(cardiac resynchronization therapy) group, n =51. The patients received routine hospital visit at 3 months of CIED implantation and meanwhile, they performed device data transmission at 3 and 6 months of Carelink remote monitoring. The time physician spent to evaluate data was collected at 3 months and the questionnaire survey was completed by physician at 6 months after CIED implantation.Results: All 54 physicians felt that Carelink remote monitoring system was simple to operate and easy to use. There were 147 patients finished hospital visit at 3 months after CIED implantation, the mean time for physician to evaluate data was(14.8±8.4) min; 150 patients finished Carelink remote monitor at 3 months after CIED implantation, the mean time for physician to evaluate data was(8.2 ±4.6) min, P〈0.0001.Conclusion: Carelink remote monitoring system was easy to use, it may save time in follow-up study which with high satisfaction in clinical practice.
关 键 词:心电描记术 便携式 心血管植入型电子器械 方案评价
分 类 号:R541.4[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222