超临界600MW湿冷机组冷端系统的改进  被引量:1

Improvement on Cold End System of a 600MW Supercritical Wet Cooling Unit

在线阅读下载全文

作  者:李永利 

机构地区:[1]神华国华(北京)电力研究院有限公司,北京100025

出  处:《发电设备》2017年第5期371-375,共5页Power Equipment

摘  要:对凝汽器、循环水泵为主的冷端系统设备的出力能力进行评估,根据汽轮机增容改造后对冷端系统设备的要求,分析计算出增容改造后冷端系统设备应具备的出力能力,并提出对应设备的改造范围、改造关键点、关键部件的选型原则,以及对比改造前后的效果。To satisfy the uprating requirement of a steam turbine, an evaluation was conducted on the capacity of its cold end equipment, such as the condenser and circulating pump, etc., together with a calculation on the capacity that the cold end equipment should have after uprating of the steam turbine. On above basis, the range and key points of the retrofit as well as the selection of corresponding equipment were proposed, while a comparison was made simultaneously on economic efficiency of the unit before and after the retrofit.

关 键 词:湿冷机组 冷端优化 经济性 

分 类 号:TK264.1[动力工程及工程热物理—动力机械及工程]

 