摘  要:通过采用厌氧工艺对煤制油费托合成废水处理进行小试论证,并采用厌氧颗粒污泥膨胀床工艺对神华宁煤生产工艺排放的煤制油费托合成废水进行工程设计和调试。实验表明,选取厌氧反应器COD容积负荷在15 kg/(m^3·d)下,COD去除率达到91%,从而证明了厌氧反应器能够实现煤制油费托合成废水处理工程化和资源化。Anaerobic process was used to treat Fischer-Tropsch synthesis wastewater from coal-to-oil process, and anaerobic granular sludge expansion process was used to design and commissioning the process. The results showed that, when COD volumetric loading was 15 kg/ (m3-d) in anaerobic reactor, the COD removal rate could reach 91%. It was proved that the anaerobic reactor could realize the engineering and resource recycling of Fiseher-Tropsch synthesis wastewater treatment in coal-to-oil process.