自来水厂采暖系统节能改造实践及分析  被引量:1

Energy saving reconstruction measures and effects of a waterworks

在线阅读下载全文

作  者:刘永强[1] 尚坚利 

机构地区:[1]山东理工大学建筑工程学院,山东淄博255049 [2]山西省临汾市自来水公司,山西临汾041000

出  处:《山东理工大学学报(自然科学版)》2017年第6期38-41,46,共5页Journal of Shandong University of Technology:Natural Science Edition

摘  要:分析了山西某净水厂原有采暖系统能耗高的原因,根据实际情况,提出了在不改动室外管网和室内采暖系统的情况下,将燃煤锅炉系统改造为水源热泵系统的方案.该方案中设置了换热器,避免了对水源污染的可能性;充分利用了该厂原有水泵资用压力,省去了常规的水源侧循环水泵,节省了投资,降低了运行能耗.最后对该系统运行以来的数据进行了统计分析,结果表明,改造取得了很好的节能效果.The paper analyzed the reasons of high energy consumption for the original heating system of a waterworks, and according to the actual situation of the project, the scheme that coalfired boiler system was transformed into water source heat pump system was put forward. At the same time, outdoor heating pipe network and indoor heating system was not reformed. The operation data for three years were analyzed, and the analysis shows that good energy saving effect has been achieved. The reform should be popularized.

关 键 词:燃煤锅炉 节能改造 采暖系统 水源热泵 

分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程] TU832

 