Optimization of Waste Gate Drive Circuit of Two-Stage Turbocharging System  

Optimization of Waste Gate Drive Circuit of Two-Stage Turbocharging System

在线阅读下载全文

作  者:Fujun Zhang Jiahang Chang Tao Cui Meng Xia 

机构地区:[1]School of Mechanical Engineering,Beijing Institute of Technology,Beijing 100081,China

出  处:《Journal of Beijing Institute of Technology》2017年第3期349-356,共8页北京理工大学学报(英文版)

基  金:Supported by the Ministerial Level Research Project of China(D2220112901)

摘  要:A two stage turbocharging control system was proposed,in which the pressure regulator valve with a close-loop pressure adjusting function instead of a high speed on-off solenoid valve,is used as a driving mechanism of waste gate.A digital-analog(DA)conversion circuit based on pulse width modulation(PWM)generates one analog voltage signal required by the pressure regulating valve control.The principle of the DA conversion circuit was analyzed,meanwhile,the performance of the conversion circuit was improved by adopting a speed-up capacitor,which helps to increase the stability and responsiveness of the control voltage generated by the conversion circuit;the structure parameters of the circuit was optimized by simulation.After the optimization,the ripple wave of circuit output voltage was kept within16mV under the 12bit conversion accuracy,the conversion time of the circuit could be reduced to 4ms.The engine bench test show that the turbocharging boost pressure control system which adopted the circuit had a rather good stable control accuracy(the steady state within 0.8%)and dynamic response(the regulation time is less than 4s).A two stage turbocharging control system was proposed,in which the pressure regulator valve with a close-loop pressure adjusting function instead of a high speed on-off solenoid valve,is used as a driving mechanism of waste gate.A digital-analog(DA)conversion circuit based on pulse width modulation(PWM)generates one analog voltage signal required by the pressure regulating valve control.The principle of the DA conversion circuit was analyzed,meanwhile,the performance of the conversion circuit was improved by adopting a speed-up capacitor,which helps to increase the stability and responsiveness of the control voltage generated by the conversion circuit;the structure parameters of the circuit was optimized by simulation.After the optimization,the ripple wave of circuit output voltage was kept within16mV under the 12bit conversion accuracy,the conversion time of the circuit could be reduced to 4ms.The engine bench test show that the turbocharging boost pressure control system which adopted the circuit had a rather good stable control accuracy(the steady state within 0.8%)and dynamic response(the regulation time is less than 4s).

关 键 词:two stage turbocharger waste gate pulse width modulation digital-analog conversion 

分 类 号:U464.135[机械工程—车辆工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象