检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:岳海玲[1] 吴海燕[2] YUE Hal-ling WU Hai-yan(The Chinese People's Armed Police Forces Academy, He- bei Langfang 065000, China Tongling Fire Detachment, Anhui Tongling 244000, China)
机构地区:[1]中国人民武装警察部队学院,河北廊坊065000 [2]铜陵市消防支队,安徽铜陵244000
出 处:《消防科学与技术》2017年第8期1087-1090,共4页Fire Science and Technology
基 金:河北省科技计划项目(16275414)
摘 要:以方型格栅和U型方通这两种常见的通透性吊顶和常见喷头及布置方式为对象,研究格栅吊顶对喷头灭火性能及现场烟气的影响。调整喷头类型、数量、距顶棚的位置,设置4个工况进行分析,得出各工况的灭火时间、温度分布。研究表明,使用同样的格栅时,下垂型喷头较直立型灭火性能好;当设置高度一定时,喷头设置在格栅下方的灭火效果较上方好;当设置同样的下垂式喷头时,方型格栅吊顶对灭火效果影响较大。With square grille ceiling and U square tube ceiling and normal layout of nozzles, the fire extinguishment performance of nozzle affected by ceiling was researched. Four scenarios with dif- ferent type, number and location of nozzles were set to get the fire extinguishing time and temperature distribution. Compared with upright nozzle, the pendant nozzle performs better in fire extin guishment in the presence of grid. When grid is set al a certain height in a place where grid ceiling is used, nozzles arranged be neath the grid show more superior reliability than those above the grid. Square grille ceiling has a greater impact on the fire suppression effect with the same pendant nozzles.
关 键 词:格栅吊顶 U型方通 喷头设置 灭火性能 温度分布
分 类 号:X924.4[环境科学与工程—安全科学] TU892[建筑科学]