机构地区:[1]Department of Resources and Environment,School of Metallurgy,Northeastern University,Shenyang 110819,China [2]Liaoning Key Laboratory of Recy-cling Science for Metallurgical Resources,Shenyang 110819,China [3]School of Materials Science and Engineering,Northeastern University,Shenyang 110819,China [4]National Engineering Research Center for Rare Earth Materials,General Research Institute for Nonferrous Metals,and Grirem Advanced Materials Co.,Ltd.,Beijing 100088,China
出 处:《Journal of Rare Earths》2017年第9期934-940,共7页稀土学报(英文版)
基 金:supported by the Key Program of National Natural Science Foundation of China(50934004);National Natural Science Foundation of China(51274061);Major State Basic Research Development Program of China(2012CBA01205);Fundamental Research Supporting Project of Northeastern University(N110602006)
摘 要:A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such as membrane composition, internal solution, concentration of SO_4^(2–), and acidity in test solution. The best performance was obtained using the membrane with PVC:DBP:HDEHP:HEH/EHP:OA mass ratio of 75:175:5:5:5. The proposed electrode exhibited a Nernstian slope of 30.44 mV/decade for Ce(Ⅳ) ion over a linear concentration range of 1×10^(–5)–1×10^(–1) mol/L with the detection limit of 9.0×10^(-6) mol/L. The electrode showed stable response within the SO_4^(2–) concentration range of 0.1–1 mol/L and the acidity range of 0.25–1.2 mol/L H+. The proposed electrode showed high selectivity for Ce(Ⅳ) over a wide variety of interfering ions and a fast response time. It was used as an indicator in the potentiometric titration of Ce(Ⅳ) solution with H_2O_2 solution, and could also be used for the determination of Ce(Ⅳ) in real Ce(Ⅳ)-containing aqueous samples.A novel Ce(Ⅳ) ion-selective polyvinyl chloride(PVC) membrane electrode based on HDEHP and HEH/EHP as ionophore was successfully prepared. The factors affecting the response of Ce(Ⅳ) ion were investigated, such as membrane composition, internal solution, concentration of SO_4^(2–), and acidity in test solution. The best performance was obtained using the membrane with PVC:DBP:HDEHP:HEH/EHP:OA mass ratio of 75:175:5:5:5. The proposed electrode exhibited a Nernstian slope of 30.44 mV/decade for Ce(Ⅳ) ion over a linear concentration range of 1×10^(–5)–1×10^(–1) mol/L with the detection limit of 9.0×10^(-6) mol/L. The electrode showed stable response within the SO_4^(2–) concentration range of 0.1–1 mol/L and the acidity range of 0.25–1.2 mol/L H+. The proposed electrode showed high selectivity for Ce(Ⅳ) over a wide variety of interfering ions and a fast response time. It was used as an indicator in the potentiometric titration of Ce(Ⅳ) solution with H_2O_2 solution, and could also be used for the determination of Ce(Ⅳ) in real Ce(Ⅳ)-containing aqueous samples.
关 键 词:Ce(Ⅳ) ion-selective electrode HDEHP HEH/EHP PVC membrane potential response rare earths
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...