大岗山电站水导瓦温偏高分析及处理  被引量:3

Analysis and Treatment of Abnormal High Temperature of the Turbine Guide Bearing in Dagangshan Hydropower Station

在线阅读下载全文

作  者:邓尧曦 戴振宇 韩军 DENG Yaoxi DAI Zhenyu HAN Jun(China Guodian Dadu River Maintenance and Installation Co. , Ltd. , Chengdu 610016, China)

机构地区:[1]国电大渡河检修安装有限公司,四川成都610016

出  处:《水电与新能源》2017年第9期66-70,共5页Hydropower and New Energy

摘  要:通过对大岗山水电站水导瓦温偏高处理方法的探讨,采用调整瓦隙和冷却系统改造等,有效地降低了瓦温,减小了不同轴瓦的温差,从而有效地降低了水轮机水导轴承瓦温过高引起的事故发生率,保证了机组安全稳定运行。The abnormal high temperature problem found in the turbine guide bearing in Dagangshan Hydropower Station is discussed. The treatment measures are introduced, including the adjustment of the bearing clearance and the renova- tion of the cooling system. After the treatment, the bearing temperature and the temperature difference between different bearing pads are effectively reduced. Thus, the safe and stable operation of the unit is ensured.

关 键 词:大岗山电站 水导瓦 瓦温过高 处理 

分 类 号:TM312[电气工程—电机]

 