检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:贾育新[1] 麦维基[1] 邱美娇[1] 黄珊珊 龙旋[1] 杨宇华[1]
机构地区:[1]广东省职业病防治院,广东广州510300 [2]南方医科大学
出 处:《中国辐射卫生》2017年第3期275-278,共4页Chinese Journal of Radiological Health
基 金:卫生行业科研专项(201002009)
摘 要:目的开展介入手术中术者眼晶状体和手指受照剂量调查,初步了解我省介入放射工作人员眼晶状体及手部剂量水平,并为给出相关的辐射防护要求提供一定的数据参考。方法 2014.7-2015.3选取两家综合大型医院进行现场调查,选择20名放射工作人员作为调查对象,共发放70套用于直接测量的指环及眼晶状体剂量计(剂量元件为Li F(Mg,Cu,P)),20套用于佩戴2个月后累积剂量调查;50套用于不同类型单台手术的剂量调查。结果 14位心内科介入诊疗人员中,眼晶体累积剂量最高达到2.64 mSv,手指剂量最高达到11.61 mSv;2位脑外科人员调查结果则分别为0.02、14.41 mSv;2位以TECA为主的介入手术人员结果分别为2.46、29.33 mSv。单次手术冠状动脉造影(CA)的眼睛体及手部剂量范围分别为0.11~0.27、0.11~0.70 mSv;冠状动脉腔内形成术(PTCA)分别为0.04~0.31、0.07~0.47 mSv;经皮冠状动脉介入治疗(PCI)分别为0.10~1.49 mSv、0.15~7.43 mSv;射频消融(RFA)分别为0.020~0.26 mSv、0.020~0.24 mSv。结论按此相当的工作量可粗估最高眼晶状体年剂量水平接近5年平均不超过20 mSv的IAEA国际限值标准,提示介入手术人员应加强眼晶状体监测及采取防护措施是必要的。Objective To investigate the operators'lens and finger radiation dose in interventional operation to get to know interventional radiology staff extremity radiation dose levels in Guangdong and to provide some reference data for giving relevant radiation protection requirements. Methods 2014.7 - 2015.3 20 interventional radiology staff in two comprehensive hospitals were selected as interviewees, who were issued 70 sets of rings and eye lens dosimeters (LiF (Mg, Cu, P) ). 20 sets of dosi- meters used to cumulative dose survey after wearing two months, while the others used to dose survey in different types single surgery. Results In 14 interventional cardiology staffs, the eye lens cumulative dose was up to 2.64 mSv, and hands dose was up to 11.61 mSv. 2 neurosurgery staffs survey results respectively while 2 TECA - based interventional surgical staffs were respectively 2.46 mSv, 29.33 mSv. The eye len and hand dose ranges in single surgical coronary angioraphy (CA) were re- spectively 0.11 - 0.27 mSv, 0. 11 - 0.70 mSv ; transluminal coronary angioplasty ( PTCA ) were respectively 0.04 - 0.31 mSv, 0.07 - 0.47 mSv ; percutaneous coronary intervention (PCI) were respectively 0.10 - 1.49 mSv, 0.15 - 7.43 mSv; ra- diofrequency ablation (RFA) were respectively MDL - 0.26 mSv, MDL - 0.24 mSv. Conclusion According to this consider- able workload, highest eye len annual dose levels were estimated roughly closer to international standard, suggesting that for surgical intervention personnel, to strengthen monitoring of the extremities and take protective measures are necessary.
分 类 号:R144.1[医药卫生—公共卫生与预防医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249