余热发电冷却水系统引起的凝汽器运行异常及处理措施  

Abnormal operation of condenser caused by cooling water system of waste heat power generation and treatment measures

在线阅读下载全文

作  者:孙景和 王震岭 王丰爱 穆永红 吴建朝 何平 SUN Jinghe WANG Zhenling WANG Fengai MU Yonghong WU Jianzhao HE Ping(Hebei Jinding Chemical Building Materials Co., Ltd., Langfang, Hebei 065903, China Zhengda Branch of Beijing Top Environmental Co., Ltd., Xingtai, Hebei 054100, China Dalian Star Huludao Cement Waste Heat Power Generation Co.,Ltd.,Huludao,Liaoning 125000, China Shanxi High Steel Waste Heat Generator Car, Xinjiang, Shanxi 044000, China)

机构地区:[1]河北金鼎化工建材有限公司,河北廊坊065903 [2]北京天壕环境股份有限公司正大分公司,河北邢台054100 [3]大连易世达葫芦岛水泥余热发电有限公司,辽宁葫芦岛125000 [4]山西高义钢铁余热发电车间,山西新绛044000

出  处:《清洗世界》2017年第9期36-40,共5页Cleaning World

摘  要:在研究大量余热发电凝汽器运行数据和总结凝汽器清洗经验的基础上,提出通过对凝汽器运行参数恶化的科学分析,判断凝汽器运行状态,着重从水处理方面归纳了应急措施,以期对小电厂凝汽器安全运行提供借鉴。Based on the study of a large number of waste heat power generation operation of condenser condenser cleaning data and summarize the experience, put forward through the analysis of the deterioration of the operation parameters of condenser, judgment of condenser running status, mainly from the water treatment were summarized, emergency measures, in safe operation of small power plant condenser condenser. order to provide reference for the

关 键 词:运行参数 应急措施 水冷表面式凝汽器 余热发电 

分 类 号:TM621.8[电气工程—电力系统及自动化]

 