摘  要:本文主要阐述了互感器综合特性现场试验有关国家标准和行业标准的不完善性,发现了当前互感器综合特性现场试验中传统电流比测量方法和互感器励磁特性低频法测量法存在的一些问题。通过对这些问题的分析,针对互感器综合特性试验给出了建议。This paper mainly expounds the imperfection of the relevant national standards and industry standards in instrument transformer comprehensive characteristic field testing . Some problems are found in instrument transformer comprehensive characteristic field testing ,especially in traditional current ratio measurement and exciting performance measurement using low- frequency power supply. Through the analysis of these problems, reasonable suggestions are provided for the instrument transformer comprehensive characteristic test.