作 者:Amit Md. Estiaque Arefin M.H. Masud Mohammad U.H. Joardder Md. Shamim Akhter
出 处:《Particuology》2017年第5期118-125,共8页颗粒学报(英文版)
摘 要:Monodisperse aerosols are essential in many applications, such as filter testing, aerosol instrument calibration, and experiments for validating models. This paper describes the design principle, construction, and performance of a monodisperse-aerosol generation system that comprises an atomizer, virtual impactor, microcontroller-based isokinetic probe, wind tunnel, and velocity measurement device. The size distribution of the produced monodisperse aerosols was determined by an optical particle counter. The effects of atomizer characteristics, the rates of minor and major flow, and solution criteria were investigated. It was found that all these parameters affect the generation of monodisperse aerosol. Finally, the expected geometric standard deviation (〈1.25) of monodisperse aerosol particles was obtained with the most suitable atomizer for 10% oleic acid in ethyl alcohol solution with 5%-15% minor flow, where the ratio between the nozzle-to-probe distance and acceleration-nozzle-exit diameter was 0.66. The con- structed monodisperse-aerosol-generation system can be used for instrumental calibration and aerosol research.Monodisperse aerosols are essential in many applications, such as filter testing, aerosol instrument calibration, and experiments for validating models. This paper describes the design principle, construction, and performance of a monodisperse-aerosol generation system that comprises an atomizer, virtual impactor, microcontroller-based isokinetic probe, wind tunnel, and velocity measurement device. The size distribution of the produced monodisperse aerosols was determined by an optical particle counter. The effects of atomizer characteristics, the rates of minor and major flow, and solution criteria were investigated. It was found that all these parameters affect the generation of monodisperse aerosol. Finally, the expected geometric standard deviation (〈1.25) of monodisperse aerosol particles was obtained with the most suitable atomizer for 10% oleic acid in ethyl alcohol solution with 5%-15% minor flow, where the ratio between the nozzle-to-probe distance and acceleration-nozzle-exit diameter was 0.66. The con- structed monodisperse-aerosol-generation system can be used for instrumental calibration and aerosol research.
关 键 词:Aerosol generation Monodisperse Design Sampling Counting
分 类 号:X513[环境科学与工程—环境工程] TN248.22[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.248