低衰变功率乏燃料棒喷淋冷却实验研究  

Experimental Research on Spray Cooling of Spent Fuel Rod with Low Decay Heat

在线阅读下载全文

作  者:韩一丹 陈丽[2] 陆道纲 苏夏[2] 王汉 段骁晗 

机构地区:[1]华北电力大学北京市非能动安全重点实验室,北京102206 [2]上海核工程研究设计院,上海200233

出  处:《原子能科学技术》2017年第10期1820-1826,共7页Atomic Energy Science and Technology

摘  要:本文基于超设计基准事故,建立1套乏燃料水池喷淋冷却实验装置,选用5×5电加热棒束模拟局部乏燃料组件,分析当乏燃料水池池水完全排空状况下,维持乏燃料包壳温度在300℃时所需的最小喷淋流量密度以及周围棒束对单棒的影响效果,并开展了低衰变功率下的喷淋冷却实验。结果表明:单棒加热功率小于25 W的加热棒束无需额外冷却操作,仍处于安全状态。分别采用流量密度2.393、2.950、3.876(m^3/h)/m^2进行喷淋冷却,可使单棒加热功率为100、125、150 W的加热棒束最高温度稳定在300℃左右。目标棒外围第1、2层棒束对其温度影响较大,第3层及其以外的加热棒束对目标棒的影响较弱。The spray cooling experiment device was built based on beyond design basis event,and the electric heated rod bundle of 5×5 was used to simulate spent fuel assemblies.The purpose of this experiment is to research the minimum spray flow density which can maintain temperature of cladding in 300 ℃ and the influence to single-rod from around heated bundle when the water of spent fuel pool is completely lost.The spray experiment to spent fuel with low decay heat was carried out in the paper.The results show that heating bundles with the power less than 25 W are in safe condition without any cooling.The spray flow density of 2.393,2.950 and 3.876(m^3/h)/m^2 can keep the temperature of heating bundles with the power of 100,125 and 150 W in 300 ℃.The greatest impact comes from the first and the second floor bundles to the temperature of target rod and the third floor bundle and others have weak influence.

关 键 词:核安全 乏燃料水池 喷淋冷却 最小喷淋流量密度 

分 类 号:TL421.1[核科学技术—核技术及应用]

 