摘  要:运行经验和试验结果表明,现有规程推荐尺寸的并联间隙存在保护失效的情况。提出一种新型的500kV复合绝缘子串并联间隙,采用单球拍-半跑道形状,XC为700 mm,XP为700 mm。经过高压试验,验证了新型并联间隙接闪雷电和转移疏导电弧的能力;采用ANSYS仿真软件,研究了装设新型并联间隙时绝缘子串表面的电场分布;经过对比和优化,提出采用加装均压环的方式,即在高压端加装一个椭圆形均压环和一个圆形均压环,在低压端加装圆形均压环,提升新型并联间隙均匀电场的能力。The experimental results and operant experiences show that the parallel gap recommend- ed by standard can' t protect the insulators efficacious. A new kind of parallel gap for the 500kV composite insulators, with the appearance of racket-half athletic track, was proposed. The XC and XP of the new parallel gap are all 700mm.The lightning protection ability of the new parallel gap was certificated by high-voltage experiments. The electric distribution of insulators with the new parallel gap was researched by ANSYS. After comparison and optimization, it is proposed to install an ellipse and a spherical grading rings on the high-pressure side and a spherical one on the low-pressure side could improve the ability to ameliorate the electric distribution of the new parallel gap.