An active base designed in high-counting-rate applications for Hamamatsu R1924A photomultiplier tube  

An active base designed in high-counting-rate applications for Hamamatsu R1924A photomultiplier tube

在线阅读下载全文

作  者:Pei-Pei Ren Wei-Ping Lin Roy Wada Xing-Quan Liu Mei-Rong Huang Guo-Yu Tian Fei Luo Qi Sun Zhi-Qiang Chen Guo-Qing Xiao Rui Han Fu-Dong Shi Bo-Xing Gou 

机构地区:[1]Institute of Modern Physics,Chinese Academy of Sciences,Lanzhou 730000,China [2]University of Chinese Academy of Sciences,Beijing 100049,China [3]Cyclotron Institute,Texas A&M University,College Station,TX 77843,USA [4]College of Physics and Electronics information,InnerMongolia University for Nationalities,Tongliao 028000,China [5]University of Science and Technology of China,Hefei 230026,China

出  处:《Nuclear Science and Techniques》2017年第10期59-63,共5页核技术(英文)

基  金:supported by the National Natural Science Foundation of China(Nos.91426301 and 11075189);the Strategic Priority Research Program of the Chinese Academy of Sciences"ADS project"(No.XDA03030200);the Program for the CAS"Light of West China"(No.29Y601030);the US Department of Energy(No.DE-FG02-93ER40773);the program of the"visiting professorship of senior international scientists of the Chinese Academy of Sciences"for their support during his stay at the IMP

摘  要:Hamamatsu R1924A is one of the most widely used photomultiplier tubes(PMTs) in nuclear physics.Since the active base suitable for R1924A is still not available in market, an active base is designed for Hamamatsu R1924A PMT, and the test results at high counting rates are presented. The active bases with two different sets of resistor chains were tested and compared by a frequency-controlled green straw hat LED light. A stable signal output up to 100 kHz is achieved using frequency-controlled LED pulsed light. The temperature of bases, which reflects the power consumption and is crucial for applications in vacuum, is also monitored with the same LED pulsed light. The temperature of the active base with smaller resistances reaches about twice of that of the active base with larger resistances in the resistor chain. For the applications in vacuum, the active base with resistance between the two sets of resistor chains may be preferable.Hamamatsu R1924A is one of the most widely used photomultiplier tubes (PMTs) in nuclear physics. Since the active base suitable for R1924A is still not available in market, an active base is designed for Hamamatsu R1924A PMT, and the test results at high counting rates are presented. The active bases with two different sets of resistor chains were tested and compared by a fre- quency-controlled green straw hat LED light. A stable signal output up to 100 kHz is achieved usingfrequency-controlled LED pulsed light. The temperature of bases, which reflects the power consumption and is crucial for applications in vacuum, is also monitored with the same LED pulsed light. The temperature of the active base with smaller resistances reaches about twice of that of the active base with larger resistances in the resistor chain. For the applications in vacuum, the active base with resistance between the two sets of resistor chains may be preferable.

关 键 词:光电倍增管 高计数率 应用 设计  活性基团 LED灯 频率控制 

分 类 号:TN152[电子电信—物理电子学] TL822.4[核科学技术—核技术及应用]

 