作 者:黄志刚[1] 张妍[1] 彭传新[1] 白雪松[1] 卓文彬[1] 闫晓[1] Huang Zhigang Zhang Yan Peng Chuanxin Bai Xuesong Zhuo Wenbin Yan Xiao(CNNC Key Laboratory on Nuclear Reactor Thermal Hydraulics Technology, Nuclear Power Institute of China, Chengdu, 610213,China)
机构地区:[1]中国核动力研究设计院中核核反应堆热工水力技术重点实验室,成都610213
出 处:《核动力工程》2017年第5期14-17,共4页Nuclear Power Engineering
摘 要:通过试验对不同内置换料水箱初始水温条件下非能动余热排出系统(PRHRS)投入后堆芯进出口温度、一回路压力、PRHRS自然循环流量和换热功率等试验数据进行了对比分析。试验结果表明:IRWST初始水温较低时,堆芯模拟体进出口水温和压力下降更快,PRHRS热交换器(HX)出口温度低,PRHRS自然循环流量变化趋势基本一致,但换热功率更高。The PRHRS operation characteristics have been experimentally studied under different initial IRWST temperature conditions. The experimental results are compared in this paper, such as core inlet/outlet temperature, system pressure, exchange power. The comparison of the experimental nature circulation flow rate of PRHRS, heat results showed that the lower initial IRWST temperature caused the core inlet/outlet temperature and system pressure drop faster, the PRHR HX outlet temperature is lower but the heat exchange power is higher, the trends of nature circulation flow rate of PRHRS is similar.
关 键 词:非能动余热排出系统(PRHRS) 换料水箱初始水温 模块式反应堆