湿式电除尘器布置策略研究  被引量:1

Layout Strategy Research for Wet Electrostatic Precipitator

在线阅读下载全文

作  者:舒喜 刘志坦[1] 惠润堂 申智勇[1] 杨爱勇[1] 李志强[1] SHU Xi LIU Zhitan HUI Runtang SHEN Zhiyong YANG Aiyong LI Zhiqiang(State Power Environmental Protection Research Institute Nanjing 210031)

机构地区:[1]国电环境保护研究院,南京210031

出  处:《工业安全与环保》2017年第10期84-87,共4页Industrial Safety and Environmental Protection

基  金:国家863计划项目(2013AA065401)

摘  要:从场地、投资、能耗、阻力、测点要求等多方面进行分析,对湿式电除尘器塔顶一体式、卧式、立式3种湿式电除尘器的布置策略进行研究。得出不同湿式电除尘技术各具优缺点,建议电厂让第三方机构根据自身实际情况进行综合技术经济分析。In this paper, the layout strategies of the 3 kinds of wet electrostatic precipitators, the integrated, horizon- tal and vertical, are studied from the field condition, investment, energy consumption, flue gas resistance, measuring point requirements and other aspects. Each kind of wet electrostatic precipitator has its own advantages and disadvantages and so it is recommended that the power plant make the third party organizations to carry out comprehensive economic and technical analysis according to their own actual situations.

关 键 词:湿式静电除尘器 布置 策略研究 