600MW亚临界汽轮机通流改造对锅炉再热器改造的影响分析  被引量:1

Analysis of the influence of 600MW subcritical steam turbine flow path optimization on the reheater reconstruction of boiler

在线阅读下载全文

作  者:李宗耀[1] 平玉环[2] 管志敏[2] 

机构地区:[1]河北国华定州发电有限责任公司 [2]华北电力大学

出  处:《冶金能源》2017年第4期46-49,共4页Energy For Metallurgical Industry

基  金:中央高校基本科研业务费专项基金;项目批准号:2015MS106

摘  要:根据600MW亚临界机组汽轮机通流改造的设计结果,对锅炉再热器改造方案的影响进行分析,优化锅炉再热器改造方案,并对优化后的改造方案进行校核计算。改造效果表明:75%THA以上工况锅炉再热蒸汽温度达到了额定值540℃,50%THA工况再热蒸汽温度提高了11℃,提高了机组运行的经济性。According to the design results of 600MW subcritical unit steam turbine flow path optimiza-tion, analyze the influence of boiler reheater reconstruction scheme, optimize the scheme of the boiler reheater, and the optimized reconstruction scheme is checked and calculated. Reconstruction results show that More than 75%THA conditions of the boiler reheat steam temperature reached the rated val-ue of 540℃ , 50%THA condition of reheat steam temperature increased by 11℃ , improved the opera-tion efficiency of the unit.

关 键 词:锅炉 汽轮机 通流改造 再热器改造 影响分析 校核计算 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 