作  者:李兰芳 曾志武[2] 王映品[2] 谢运祥[2] 徐晓刚 黄嘉健 张晓宇[2] LI Lan-fang ZENG Zhi-wu WANG Ying-pin XIE Yun-xiang XU Xiao-gang HUANG Jia-jian ZHANG Xiao-yu(Electric Power Research Institute, Guangdong Power Grid Co. Ltd. , Guangzhou 510080, China School of Electric Power, South China University of Technology, Guangzhou 510640, China)

机构地区:[1]广东电网有限公司电力科学研究院,广东广州510080 [2]华南理工大学电力学院,广东广州510640

出  处:《电工电能新技术》2017年第11期79-88,共10页Advanced Technology of Electrical Engineering and Energy

基  金:国家自然科学基金项目(61104181);中国南方电网有限责任公司科技项目(GDKJXM00000015)

摘  要:谐波和无功检测技术在电能质量治理装置的应用中起着重要作用,检测结果的准确性、实时性和抗干扰性是保证装置的补偿工作性能的前提条件。本文介绍了现有6种时域的谐波和无功检测方法的工作原理,并根据电源电压和负载电流是否三相平衡及包含谐波和无功与否等不同情况设计了8种不同的工况。在这8种不同工况下,结合6种谐波和无功检测算法,并将其应用于三相三线制有源电力滤波器(APF)系统中,使用Matlab/Simulink软件分别对各种不同组合的工况进行仿真分析。根据仿真结果,对比分析了各种组合下的谐波和无功补偿指令信号、有功和无功功率及其功率因数。总结了所采用的APF系统在不同工况下各种检测算法的检测性能,分析了各种算法所适用的工况。实验验证了理论分析和仿真结果的正确性。本文的研究成果为电能质量治理及其控制算法的研究提供了理论参考,为电能质量治理装置的设计与研发提供了切实可行的依据。Harmonic and reactive power detection technique plays an important role in the applications of power quality control devices. The accuracy,real-time performance and anti-interference of the detection results are the preconditions to ensure the compensation performance of the device. This paper introduces the working principle of6 kinds of harmonic and reactive power detection methods,and 8 different working conditions are designed according to whether the power supply voltage and load current are balanced or not,including harmonic and reactive power or not. Under these 8 different conditions,combining 6 kinds of harmonic and reactive power detection algorithm,Matlab/Simulink software was used to simulate under the working conditions of different combinations applying to three-phase three wire active power filter( APF) system. According to the simulation results,the harmonic and reactive power compensation signals,reactive power and power factor are analyzed and compared. The detection performance of various detection algorithms under different working conditions is summarized,and the working conditions suited with various algorithms are analyzed. The experimental results verify the correctness of the theoretical analysis and simulation results. The research results of this paper provide a theoretical reference for the research of power quality control and control algorithm,and provide a practical basis for the design and development of power quality control devices.

关 键 词:电能质量 检测方法 三相平衡 谐波和无功 功率因数 

分 类 号:TM714.3[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象