摘  要:针对保护或断路器出现拒动条件下,保护期望动作状态计算结果与实际动作逻辑间可能出现失配的原因进行了分析。通过计及主保护、近后备保护、远后备保护和断路器失灵保护间相互制约关系,给出了一种电网故障诊断模型解析规则的改进方法。仿真算例表明,所提方法能够提高故障诊断模型目标函数的计算精度,获得更加合理的故障诊断结果。In allusion to the occurrence of misoperation in protective relays and circuit breakers, this paper analyzed the cause that the calculating results of expected action state mismatched the actual operation results of protective relays. By considering the mutual interaction relationship among main protection, near backup protection, far backup protection and circuit breakers failure protection, this paper gave the amended analytical rules of a kind of grid fault diagnosis model. Simulation examples show the proposed method may improve the calcula-tion accuracy of object functions of fault diagnosis models, and thus obtain more reasonable fault diagnosis results.