检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张世宏 刘正强 聂鑫[3] 杨冬[3] 员盼锋[4]
机构地区:[1]国家电投集团河南电力有限公司技术信息中心,河南郑州450001 [2]国家电投集团河南电力有限公司平顶山发电分公司,河南平顶山467300 [3]西安交通大学动力工程多相流国家重点实验室,陕西西安710049 [4]西安热工研究院有限公司,陕西西安710054
出 处:《热力发电》2017年第11期44-49,共6页Thermal Power Generation
基 金:国家科技支撑计划项目(2015BAA03B01)~~
摘 要:针对平顶山电厂超超临界机组直流锅炉水冷壁壁温偏差过大的问题,本文根据锅炉结构特点和对冲燃烧特性,建立了1 000 MW机组对冲燃烧锅炉水动力计算模型,并通过对比计算结果和试验实测数据,反推锅炉热负荷分布,分析了造成锅炉水冷壁壁温偏差过大的原因,提出了相关应对措施。研究结果表明:该机组锅炉水冷壁壁温偏差过大主要是由炉膛内热负荷不均和流量分配不均引起,同时锅炉结构也对壁温偏差的敏感度有一定的影响;在高电负荷时,计算结果与实测数据能够较好地吻合,但中低电负荷时,水冷壁吸热偏差较大,通过反推,修正了热负荷分布,发现计算值与实测结果接近。建议在运行过程中注意调整同层旋流燃烧器的风粉均匀分配,在变负荷或扰动工况时控制好煤水比,在锅炉设计方面可以调整进入上炉膛前墙和后墙的流动截面比,使流量均匀分配。To solve the large water wall temperature deviation problem occurred on ultra supercritical 1 000 MW unit boiler of Pingdingshan Power Plant, a mathematical model for the 1 000 MW unit boiler was established according to the boiler structure and the heat load distribution features in the furnace. By comparing the calculated results and the measured data, the boiler heat load distribution was deduced, and the reasons for the excessive deviation of the boiler water wall temperature were analyzed. The results show that, the uneven heat load and uneven flow distribution in the furnace mainly leads to the large temperature deviation. In addition, the structure of the boiler has a certain influence on sensitivity of the wall temperature deviation. The calculation results and the measured data can be in good agreement at high load. But there is a big difference between the calculated steam temperature and the measured data. However, when the heat load distribution in the furnace is modified time after time, it indicates that the calculation results agree with the field data well. It suggests to adjust the uniform distribution of pulverized-coal and air in the same layer swirl burner during the operation. The ratio of coal to water should be controlled under variable load or disturbance conditions. Moreover, in boiler design, the flow cross ratio of the front wall and the back wall in the upper furnace can be adjusted, so that the flow can be evenly distributed.
关 键 词:超超临界 锅炉 水冷壁 吸热偏差 出口汽温 水动力计算 煤水比
分 类 号:TK223.3[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.52