HORIBA HR型激光拉曼光谱仪的使用和维护  被引量:4

The Operation and Maintenances of HORIBA HR Raman Spectrometer

在线阅读下载全文

作  者:公祥南[1] 郭莉杰 周小元[1,2] 邹函君[1] 

机构地区:[1]重庆大学分析测试中心,重庆401331 [2]重庆大学物理学院,重庆401331

出  处:《实验室研究与探索》2017年第10期299-303,共5页Research and Exploration In Laboratory

摘  要:激光拉曼光谱仪属于大型开放性仪器,掌握仪器的基本原理并且正确使用和维护仪器显得尤为重要。通过对影响HORIBA HR型激光拉曼光谱仪仪器性能的4个方面逐一讨论,包括仪器校准与调试、样品种类选择、合适测试参数设置、仪器保养与维护,不仅可以获得可靠、优质的拉曼光谱数据,更能提高仪器的使用效率、降低仪器故障率。Laser Raman spectrometer belongs to large opening instrument, it is important to master the basic principle, use and maintenance of the spectrometer, correctly. Not only reliable, high-quality Raman spectra data can be obtained, but also the service efficiency of the instrument can be improved, the failure rate can be reduced through the influence HORIBA HR Raman spectrometer instrument performance of four aspects discussion which includes instrument calibration and debugging, sample types, suitable parameters setting and instrument maintenance.

关 键 词:激光拉曼光谱仪 校准 测试参数 仪器维护 

分 类 号:TH74[机械工程—光学工程]

 