胸锁关节超声检查对透析相关淀粉样变的诊断价值  被引量:1

The value of sternoclavicular joint ultrasonography in the diagnosis of dialysis-related amyloidosis

在线阅读下载全文

作  者:翟林[1] 王思宇 薛菲[2] 张丹[1] 姚英[2] 

机构地区:[1]首都医科大学附属复兴医院超声影像科,北京100038 [2]首都医科大学附属复兴医院肾内科,北京100038

出  处:《中国血液净化》2017年第11期732-735,共4页Chinese Journal of Blood Purification

基  金:首都医科大学基础临床研究课题(16JL76)

摘  要:目的应用高频超声检查透析患者胸锁关节,探讨超声诊断透析相关性淀粉样变(dialysisrelated amyloidosis,DRA)的临床价值。方法选择为68例长期血液透析患者为研究对象,对照组为40例健康体检者,按透析时间将透析患者分为≤5年组(Ⅰ组)、5~10年组(Ⅱ组),>10年组(Ⅲ组)。高频超声检查胸锁关节,测量锁骨胸骨端前侧骨膜表面至关节囊外缘之间的最大距离(D),以任意一侧胸锁关节D值>2mm即认为阳性,检查关节面的平整性,同时测定血液透析患者血清β2-微球蛋白(β2-microglobulin,β2-M)水平。结果研究组胸锁关节D值明显高于对照组,组间可见显著性差异(右侧F=16.895,P<0.001,左侧F=19.812,P<0.001),左右两侧对比未见显著性差异(P>0.05);对照组及研究组胸锁关节阳性率分别为对照组5%,Ⅰ组50.0%,Ⅱ组61.5%,Ⅲ组86.4%,可见显著性差异(χ2=43.628,P<0.001),D值与透析时间呈线性相关(r=0.412,P=0.021);透析患者β2-M明显增高,但3组透析患者间未见显著性差异(F=1.855,P=0.167)。结论胸锁关节囊及滑膜增厚可提示透析患者DRA的发生,为DRA的早期诊断和定期复查提供了一种简便经济并且无创的检查手段。Objective To evaluate the usefulness of high frequency ultrasonography of sternoclavicular (SC) joint for the diagnosis of dialysis-related amyloidosis (DRA). Methods Sixty-eight maintenance hemo-dialysis (MHD) patients and forty normal individuals as the controls were enrolled in this study. MHD pa-tients were then subdivided into three groups by MHD duration:group I≤5 years, group II 5~10 years and group III〉10 years. Ultrasonography of the SC joint was performed bilaterally for patients and controls. The maximum distance (D) between anterior periosterum surface of clavicle and the outer edge of joint capsule and the smoothness of the articular surface were determined by high frequency ultrasonography. D value〉2mm at any side was defined as a positive finding. Serumβ2 microglobulin (β2-M) level was measured at the same time. Results D value of SC joint was significantly higher in MHD patients than in normal controls, and was also significantly different among the four groups (right, F=16.895, P〈0.001; left, F=19.812, P〈0.001). There was no different between left side and right side (P〉0.05). The positive rate of SC joint was 5%in control group, 50.0%in group I, 61.5%in group II and 86.4%in group III (χ2=43.628, P〈0.001), indi-cating a correlation between D value and hemodialysis duration (r=0.412, P〈0.05). Serumβ2-M was signifi-cantly higher than the normal value in MHD patients. There was no significant difference in serum β2-M among the three groups of MHD patients (F=1.855, P=0.167). Conclusions The capsule and synovium of the SC joint become thicker as the dialysis duration prolonged. High frequency ultrasonography of SC joint is a less expensive and noninvasive method for the early diagnosis and fellow-up of DRA.

关 键 词:超声检查 胸锁关节 血液透析 淀粉样变 

分 类 号:R318[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象