Error analysis and Stokes parameter measurement of rotating quarter-wave plate polarimeter  被引量:1

Error analysis and Stokes parameter measurement of rotating quarter-wave plate polarimeter

在线阅读下载全文

作  者:支丹丹 李健军 高冬阳 翟文超 黄雄豪 郑小兵 

机构地区:[1]Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Key Laboratory of Optical Calibration and Characterization, Hefei 230031, China [2]University of Science and Technology of China, Hefei 230026, China

出  处:《Chinese Physics B》2017年第12期242-247,共6页中国物理B(英文版)

基  金:Project supported by the National High Technology Research and Development Program of China(Grant No.2015AA123702);the National Natural Science Foundation of China(Grant No.61505222)

摘  要:In this paper, we present a simple Stokes parameter measurement method for a rotating quarter-wave plate polarimeter. This method is used to construct a model to describe the principle of how the magnitudes of errors influence the deviation of the output light Stokes parameter, on the basis of accuracy analysis of the retardance error of the quarter-wave plate, the misalignment of the analyzing polarizer, and the phase shift of the measured signals, which will help us to determine the magnitudes of these errors and then to acquire the correct results of Stokes parameters. The method is validated by the experiments on left-handed circularly polarized and linear horizontal polarization beams. With the improved method, the maximum measurement deviations of Stokes parameters for these two different polarized states are reduced from 2.72% to 2.68%, and from 3.83% to 1.06% respectively. Our results demonstrate that the proposed method can be used as a promising approach to Stokes parameter measurement for a rotating quarter-wave plate polarimeter.In this paper, we present a simple Stokes parameter measurement method for a rotating quarter-wave plate polarimeter. This method is used to construct a model to describe the principle of how the magnitudes of errors influence the deviation of the output light Stokes parameter, on the basis of accuracy analysis of the retardance error of the quarter-wave plate, the misalignment of the analyzing polarizer, and the phase shift of the measured signals, which will help us to determine the magnitudes of these errors and then to acquire the correct results of Stokes parameters. The method is validated by the experiments on left-handed circularly polarized and linear horizontal polarization beams. With the improved method, the maximum measurement deviations of Stokes parameters for these two different polarized states are reduced from 2.72% to 2.68%, and from 3.83% to 1.06% respectively. Our results demonstrate that the proposed method can be used as a promising approach to Stokes parameter measurement for a rotating quarter-wave plate polarimeter.

关 键 词:POLARIZATION stokes parameter detection POLARIMETER 

分 类 号:O436.3[机械工程—光学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象