银川市地埋管地源热泵系统利用潜力分析  被引量:1

Utilization potential of ground-source heat pump system in Yinchuan

在线阅读下载全文

作  者:杨超[1,2] 钱会[1] 扈志勇[2] 郁冬梅[2] 

机构地区:[1]长安大学环境科学与工程学院,陕西西安710054 [2]宁夏国土资源调查监测院,宁夏银川750004

出  处:《宁夏工程技术》2017年第3期221-224,共4页Ningxia Engineering Technology

基  金:银川市浅层地温能调查评价项目(1212011120162)

摘  要:根据银川市浅层地温能资源赋存条件,综合考虑地埋管地源热泵开发利用的各地层影响因素,结合层次分析法对地埋管地源热泵系统的开发利用进行适宜性分区。结果表明,银川市地埋管地源热泵开发利用只有适宜区与较适宜区,无不适宜区,说明地埋管地源热泵系统在银川市具有较好的开发利用地质条件。通过对研究区浅层地温能资源量的计算及经济、社会效益的分析,发现研究区浅层地温能具有相当可观的开发利用量,对其开发利用可减少大量大气污染物的排放。According to the occurrence conditions of shallow geothermal energy resources in Yinchuan City, suitability division of ground-source heat pump was analyzed comprehensively considered the development and utilization of the ground source using the analytic hierarchy process. The result shows that there are only favorable region and suitable region, and no unsuitable region for the development and utilization of ground source heat pump in Yinchuan area. It shows that there are good geological conditions for development and utilization of ground-source heat pump system. Based on the calculation of the shallow geothermal energy resources in the study area, the economic and social benefits are also analyzed. It is found that the shallow geothermal energy in the study area has considerable development and utilization, which will reduce the emission of air pollutants.

关 键 词:浅层地温能 地埋管地源热泵 层次分析法 适宜性分区 换热功率 

分 类 号:TQ356[化学工程]

 