烟气温湿度对电除尘脱除细颗粒的影响  被引量:4

Effects of temperature and humidity on electrostatic precipitator removal of fine particles

在线阅读下载全文

作  者:胡斌[1] 周磊[1] 孙宗康 梁财[1] 杨林军[1] 

机构地区:[1]东南大学能源热转换及其过程测控教育部重点实验室,南京210096

出  处:《东南大学学报(自然科学版)》2017年第6期1148-1153,共6页Journal of Southeast University:Natural Science Edition

基  金:国家重点基础研究发展计划(973计划)资助项目(2013CB228505);国家重点研发计划资助项目(2016YFC0203700)

摘  要:采用搭建的350 m^3/h燃煤热态实验平台,测量电除尘出口不同粒径细颗物脱除效率,考察喷雾降温对电除尘放电特性、烟气酸露点、粉尘比电阻及除尘效率的影响.结果表明:当烟气温度由130℃降低到90℃,相对湿度由6%提高到12%时,电除尘击穿电压升高,粉尘比电阻降低;同时烟气酸露点温度随着相对湿度增加而提高;电除尘质量脱除效率变化不明显,但在0.1~1.0μm区间的颗粒数量脱除效率可提高10%;根据低低温电除尘运行经验可知,喷水降温到烟气酸露点以下,合理控制烟气灰硫比可避免产生烟道腐蚀.Coal-fired thermal state experimental platform with 350 m^3/h was designed,the grade removal efficiencies of different fine particles at the electrostatic precipitator(ESP) outlet were measured.ESP discharge characteristics,flue gas acid dew point,dust resistivity,and dust removal efficiency were investigated with different flue gas temperatures and humidities.The results show that the ESP breakdown voltage raises and the dust resistivity reduces,when the flue gas temperature reduces from 130 ℃ to 90 ℃ and the relative humidity improves from 6% to 12%.Meanwhile,the acid dew point also increases.The ESP dust removal efficiency is not obviously improved,but the removal efficiencies(defined as through the window number) of particles from 0.1 μm to 1.0 μm are increased by 10%.When spaying the water droplet,the control of the flue gas ash and sulfur ratio can avoid the corrosion in the flue gas.

关 键 词:电除尘 喷雾调质 脱除效率 PM2.5 

分 类 号:X701.2[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象