检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杜健[1,2] 王帅斌 王倩[1,2] 樊强 李宁[1,2]
机构地区:[1]环境保护部标准样品研究所,北京100029 [2]国家环境保护污染物计量和标准样品研究重点实验室,北京100029
出 处:《化工环保》2017年第6期713-718,共6页Environmental Protection of Chemical Industry
摘 要:采用称量法通过两步稀释制备了含量水平为1μmol/mol的氮气中正己烷气体标准样品,考察了气瓶内壁吸附作用、制备重现性、瓶内均匀性、时间稳定性等相关因素的影响,并将该正己烷气体标准样品与同类气体标准样品进行了比较。结果表明:该正己烷气体标准样品的最低使用压力为1 MPa,有效期为12个月(0~38℃),相对扩展不确定度(k=2)为2%;该正己烷气体标准样品的量值与同类标准样品具有可比性,可为相关环境监测工作提供技术支持。The n-hexane standard gas with 1 μmol/mol of concentration level was prepared in nitrogen by gravimetric method and two-step dilution process. The affecting factors were investigated, such as: the adsorbability of the cylinder inner wall, the reproducibility of the preparation process, the uniformity and time stability of gas in the cylinder. Moreover, the n-hexane standard gas was compared with other same type standard sample. The result showed that: The minimum using pressure was 1 MPa, the valid term was 12 months (at 0-38 ℃ ) and the relative expanded uncertainty (k=2) was 2% for the n-hexane standard gas; The value of the n-hexane standard gas was comparable to the same type standard sample, which could provide technical support for environmental monitoring.
分 类 号:X830.5[环境科学与工程—环境工程]