机构地区:[1]福建省肿瘤医院消毒供应中心,福建福州350000
出 处:《中国卫生标准管理》2017年第27期145-148,共4页China Health Standard Management
摘 要:目的探讨利用根本原因分析法(RCA)在消毒供应中心待灭菌腔镜器械质量控制中的应用效果。方法成立质量控制小组,应用根本原因分析法(RCA),对消毒供应中心待灭菌腔镜器械的各阶段进行分析,查找根本原因,针对要因采用PDCA循环进行改进,确保待灭菌腔镜器械质量得到控制。结果应用根本原因分析法前后,待灭菌腔镜器械不合格率明显下降(P<0.01),根本原因分析法有效地提高待灭菌腔镜器械的质量。结论应用根本原因分析法有效降低待灭菌腔镜器械的不合格率,提高待灭菌腔镜器械的质量。Objective To explore the application of root cause analysis (RCA) in quality control of sterilization endoscopes in disinfection supply center. Methods The quality control team was set up. The root cause analysis (RCA) was applied to analyze the various stages of sterilization endoscope equipment in the disinfection supply center to find out the root causes. The PDCA cycle should be improved to ensure the quality of the endoscopic instruments to be controlled. Results Before and after the application of root cause analysis, the failure rate of endoscopic instruments to be sterilized decreased significantly (P 〈 0.01). The root cause analysis method effectively improved the quality of endoscopic instruments to be sterilized. Conclusion The root cause analysis method can effectively reduce the failure rate of endoscopic instruments to be sterilized and improve the quality of endoscopic instruments to be sterilized.