研究堆乏燃料贮存架抗震计算  被引量:6

Seismic Calculation of Spent Fuel Storage Rack for Research Reactor

在线阅读下载全文

作  者:李成业[1] 王万金[1] 吴伟[1] 廖佳涛[1] 

机构地区:[1]中国核动力研究设计院,四川成都610041

出  处:《机械设计与制造》2018年第1期202-204,208,共4页Machinery Design & Manufacture

基  金:国家自然科学基金中子及带电粒子辐照对国产含铌新锆合金中第二相的影响研究(51601185)

摘  要:乏燃料贮存架是核设施中安全级设备,其自由放置在乏燃料水池中,对其进行抗震分析具有重要意义。针对某研究堆乏燃料贮存架的特点,采用谱分析法和简化模型-时程分析法相结合的分析方法对乏燃料贮存架进行抗震计算,克服了谱分析法和时程分析法各自缺点,提高了乏燃料贮存架抗震计算效率。计算结果表明,研究堆乏燃料贮存架具有足够的结构强度贮备,在各种工况下均能保持结构稳定性和完整性,不发生倾覆,不与池壁发生碰撞,满足相关规范要求。Spent fuel storage rack is a key equipment of nuclear facility. And it is freestanding in spent fuel pool. Therefore, it is very important for seismic analysis of the rack. In this study, response spectrum and time history analysis method was used to perform seismic calculation for spent fuel storage rack of research reactor. The techniques overcame shortcomings of both methods and improve efficiency. As the calculated results, the rack had sufficient structural strength and was safe with any specific condition. Besides, the rack didn't jump and bump into the wall of the pool. The results proved that the design satisfied requirements of specifications.

关 键 词:乏燃料贮存架 抗震分析 安全评定 研究堆 